This unit supports OTA (over-the-air) firmware updating capabilities. This means that it can automatically detect newer firmware versions from the Web UI once they are released and prompt for update when the Cloud services are enabled.
Important Notes
- AC-AXION-OUT-HDBT Optimize CEC control
- Added Input HDCP request command
- : <SET INx HP HDCP y><GET INx HP HDCP>
- y= 0-1, (0= Default/ Request HDCP), (1= Do Not Request HDCP)
- Add SET INx RST
- Add CMD SET OUTx TP/HP RST
- Add SET OUTx TP POE y[y:0=Auto,1=Force EN,2=Force DIS]
- Fix issue where MAC address could change on product reboot.
- Fix issue where setting static IP address on Web UI would revert after reboot.
- Fix issue where EDID would not copy from HDBT outputs
- Fix SDDP notify-alive max-age response time from 90 to 1800 seconds
- Added HDBT Output Colorspace Setting
- Added card type information on the I/O Config page
- Remove IR matrix settings from web interface (available via API commands)
- Removed temperature data from System page (due to specific browser parsing issues, will return later)
- Hide unused card slots from web interface (I/O Settings and Matrix pages)
- Users will be notified of system connection interruptions and prompted to Refresh the web UI.
- Added Auto-Scroll toggle checkbox to disable auto-scrolling to aid in diagnostics/readability
- Add Console page "Export Log" and "Clear Console" buttons on Web UI
- Remove System page RS232 settings.
- Fix issue where MAC address could change on product reboot.
- Fix issue where setting static IP address on Web UI would revert after reboot.